Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.887
Filtrar
1.
Ying Yong Sheng Tai Xue Bao ; 35(3): 858-866, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38646774

RESUMO

Insect visual electrophysiological techniques are important to study the electrical characteristics of photoreceptor cells and visual neurons in insects, including electroretinography (ERG) and microelectrode intracellular recording (MIR). ERG records the changes of voltage or electric current in the retina of insects in response to different light stimuli, which occurs outside the cell. MIR records the changes in individual photoreceptor cells or visual neurons of an insect exposed to different lights, which occurs inside the cell. Insect visual electrophysiological techniques can explore the mechanism of electrophysiological response of insects' vision to light and reveal their sensitive light spectra and photoreceptor types. This review introduced the basic structure and the principle of ERG and MIR, and summarized their applications in insect researches in the past 20 years, which would provide references for elucidating the mechanism of light perception in insects and the use of insect phototropism to control pests.


Assuntos
Eletrorretinografia , Insetos , Células Fotorreceptoras de Invertebrados , Animais , Insetos/fisiologia , Eletrorretinografia/métodos , Células Fotorreceptoras de Invertebrados/fisiologia , Visão Ocular/fisiologia , Microeletrodos , Fenômenos Eletrofisiológicos , Eletrofisiologia/métodos
2.
STAR Protoc ; 5(1): 102909, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38427565

RESUMO

Here, we present a protocol for the fabrication of transparent implantable electrode arrays for integrating optogenetics and electrophysiology. We describe steps for fabricating microelectrodes using the conductive polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate). We then detail procedures for analyzing performance of the electrodes and recording light-evoked neural activities from the transgenic mouse. This protocol utilizes photolithography rather than conventional electrodeposition. For complete details on the use and execution of this protocol, please refer to Cho et al. (2022).1.


Assuntos
Optogenética , Roedores , Camundongos , Animais , Microeletrodos , Eletrodos Implantados , Camundongos Transgênicos , Eletrofisiologia/métodos
3.
Nature ; 624(7991): 295-302, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38092907

RESUMO

Connecting different electronic devices is usually straightforward because they have paired, standardized interfaces, in which the shapes and sizes match each other perfectly. Tissue-electronics interfaces, however, cannot be standardized, because tissues are soft1-3 and have arbitrary shapes and sizes4-6. Shape-adaptive wrapping and covering around irregularly sized and shaped objects have been achieved using heat-shrink films because they can contract largely and rapidly when heated7. However, these materials are unsuitable for biological applications because they are usually much harder than tissues and contract at temperatures higher than 90 °C (refs. 8,9). Therefore, it is challenging to prepare stimuli-responsive films with large and rapid contractions for which the stimuli and mechanical properties are compatible with vulnerable tissues and electronic integration processes. Here, inspired by spider silk10-12, we designed water-responsive supercontractile polymer films composed of poly(ethylene oxide) and poly(ethylene glycol)-α-cyclodextrin inclusion complex, which are initially dry, flexible and stable under ambient conditions, contract by more than 50% of their original length within seconds (about 30% per second) after wetting and become soft (about 100 kPa) and stretchable (around 600%) hydrogel thin films thereafter. This supercontraction is attributed to the aligned microporous hierarchical structures of the films, which also facilitate electronic integration. We used this film to fabricate shape-adaptive electrode arrays that simplify the implantation procedure through supercontraction and conformally wrap around nerves, muscles and hearts of different sizes when wetted for in vivo nerve stimulation and electrophysiological signal recording. This study demonstrates that this water-responsive material can play an important part in shaping the next-generation tissue-electronics interfaces as well as broadening the biomedical application of shape-adaptive materials.


Assuntos
Eletrofisiologia , Polímeros , Água , Animais , alfa-Ciclodextrinas/química , Eletrodos , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Eletrofisiologia/tendências , Coração , Músculos , Polietilenoglicóis/química , Polímeros/química , Seda/química , Aranhas , Água/química , Hidrogéis/química , Eletrônica/instrumentação , Eletrônica/métodos , Eletrônica/tendências
4.
J Mater Chem B ; 11(40): 9639-9657, 2023 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-37610228

RESUMO

The combination of electrophysiology and neuroimaging methods allows the simultaneous measurement of electrical activity signals with calcium dynamics from single neurons to neuronal networks across distinct brain regions in vivo. While traditional electrophysiological techniques are limited by photo-induced artefacts and optical occlusion for neuroimaging, different types of transparent neural implants have been proposed to resolve these issues. However, reproducing proposed solutions is often challenging and it remains unclear which approach offers the best properties for long-term chronic multimodal recordings. We therefore created a streamlined fabrication process to produce, and directly compare, two types of transparent surface micro-electrocorticography (µECoG) implants: nano-mesh gold structures (m-µECoGs) versus a combination of solid gold interconnects and PEDOT:PSS-based electrodes (pp-µECoGs). Both implants allowed simultaneous multimodal recordings but pp-µECoGs offered the best overall electrical, electrochemical, and optical properties with negligible photo-induced artefacts to light wavelengths of interest. Showing functional chronic stability for up to four months, pp-µECoGs also allowed the simultaneous functional mapping of electrical and calcium neural signals upon visual and tactile stimuli during widefield imaging. Moreover, recordings during two-photon imaging showed no visible signal attenuation and enabled the correlation of network dynamics across brain regions to individual neurons located directly below the transparent electrical contacts.


Assuntos
Cálcio , Optogenética , Eletrodos Implantados , Optogenética/métodos , Eletrofisiologia/métodos , Ouro
5.
J Vis Exp ; (196)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37335110

RESUMO

In vivo electrophysiology provides unparalleled insight into the sub-second-level circuit dynamics of the intact brain and represents a method of particular importance for studying mouse models of human neuropsychiatric disorders. However, such methods often require large cranial implants, which cannot be used in mice at early developmental time points. As such, virtually no studies of in vivo physiology have been performed in freely behaving infant or juvenile mice, despite the fact that a better understanding of neurological development in this critical window would likely provide unique insights into age-dependent developmental disorders such as autism or schizophrenia. Here, a micro-drive design, surgical implantation procedure, and post-surgery recovery strategy are described that allow for chronic field and single-unit recordings from multiple brain regions simultaneously in mice as they age from postnatal day 20 (p20) to postnatal day 60 (p60) and beyond, a time window roughly corresponding to the human ages of 2 years old through to adulthood. The number of recording electrodes and final recording sites can be easily modified and expanded, thus allowing flexible experimental control of the in vivo monitoring of behavior- or disease-relevant brain regions across development.


Assuntos
Transtorno Autístico , Encéfalo , Camundongos , Humanos , Animais , Recém-Nascido , Eletrofisiologia/métodos , Eletrodos Implantados , Encéfalo/cirurgia , Encéfalo/fisiologia , Comportamento Animal/fisiologia
6.
Curr Protoc ; 3(5): e769, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37154436

RESUMO

Behavioral neuroscience has long relied on in vivo electrophysiology to provide spatially and temporally precise answers to complex questions about the neural dynamics underlying sensory processing and action execution. Investigating the neural correlates of behavior can be challenging in freely behaving animals, especially when making inferences related to internal states that are temporally or conceptually ambiguous, such as decision-making or motivation. This necessitates careful creation of appropriate and rigorous controls and awareness of the many potential confounds when attributing neural signals to animal behavior. This article discusses fundamental considerations for the optimal design and interpretation of in vivo rodent electrophysiological recording experiments and focuses on the different optimization strategies required when investigating neural encoding of external stimuli versus free behavior. The first protocol offers suggestions specific to intracranial surgical implantation of multielectrode arrays. The second protocol delves into optimization strategies and tips useful for designing and interpreting recording experiments conducted in freely behaving rodents. © 2023 Wiley Periodicals LLC. Basic Protocol 1: Surgical implantation of the multielectrode array Basic Protocol 2: Optimizing experimental design and parameters.


Assuntos
Comportamento Animal , Animais , Eletrodos Implantados , Comportamento Animal/fisiologia , Eletrofisiologia/métodos
7.
Curr Protoc ; 3(3): e650, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36912603

RESUMO

This article presents detailed descriptions of procedures and troubleshooting tips for solid-supported membrane (SSM)-based electrophysiology assays (SURFE²R) to measure electrogenic solute carrier transporter proteins (SLCs) and assess the effects of compounds that modulate their activity. SURFE²R allows the use of the standard 96-well format, making it an ideal platform for tertiary assays in a drug-discovery campaign. The assays are performed with cell-line-derived membrane fractions or proteoliposomes containing the transporter of interest. Three main protocols are described for the isolation of membrane fractions from cell culture and the generation of proteoliposomes containing the transporter of interest. Additionally, detailed protocols for SURFE²R single concentration and dose-response experiments are included to measure the potencies of test compounds in stimulating or inhibiting transporter function (EC50 or IC50 values, respectively) and kinetic functional assays to calculate apparent affinity (kM ) and maximal velocity (Vmax ) of substrate uptake. © 2023 Sanofi. Current Protocols published by Wiley Periodicals LLC. PROTOCOL GROUP 1: Sample preparation for SSM-based electrophysiology assays Support Protocol 1: Production of cell batches Support Protocol 2: Simple isolation of cell membranes Alternate Protocol 1: Isolation of cell membranes with sucrose gradient pre-purification Support Protocol 3: Production and isolation of liposomes Support Protocol 4: Preparation of sensor with isolated cell membranes Alternate Protocol 2: Preparation of sensor with isolated proteoliposomes PROTOCOL GROUP 2: Determination of assay parameters for SSM-based electrophysiology assay Support Protocol 5: Assay with stable buffer Alternate Protocol 3: Assay with ion gradient Support Protocol 6: Determination of membrane/liposome concentration Support Protocol 7: Determination of substrate dependency kM PROTOCOL GROUP 3: Determination of advanced assay parameters for SSM-based electrophysiology assays Support Protocol 8: Assessment of ion concentration dependency Support Protocol 9: Assessment of pH dependency Support Protocol 10: Assessment of DMSO dependency Support Protocol 11: Assessment of signal stability with multiple activations PROTOCOL GROUP 4: Compound testing through SSM-based electrophysiology assays using SURFE²R apparatus Support Protocol 12: Assessment of signal specificity of a published inhibitor or unknown compound(s) Support Protocol 13: Compound wash-out Support Protocol 14: Statistical analysis.


Assuntos
Descoberta de Drogas , Proteínas de Membrana Transportadoras , Eletrofisiologia/métodos , Proteínas de Membrana Transportadoras/metabolismo , Membranas/metabolismo , Membrana Celular/metabolismo , Lipossomos
8.
Biosens Bioelectron ; 228: 115223, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36931193

RESUMO

Organoids are emerging in vitro models of human physiology. Neural models require the evaluation of functional activity of single cells and networks, which is commonly measured by microelectrode arrays. The characteristics of organoids clash with existing in vitro or in vivo microelectrode arrays. With inspiration from implantable mesh electronics and growth of organoids on polymer scaffolds, we fabricated suspended hammock-like mesh microelectrode arrays for neural organoids. We have demonstrated the growth of organoids enveloping these meshes and the culture of organoids on meshes for up to one year. Furthermore, we present proof-of-principle recordings of spontaneous electrical activity across the volume of an organoid. Our concept enables a new class of microelectrode arrays for in vitro models of three-dimensional electrically active tissue.


Assuntos
Técnicas Biossensoriais , Telas Cirúrgicas , Humanos , Microeletrodos , Organoides , Eletrofisiologia/métodos
9.
Cold Spring Harb Protoc ; 2023(10): pdb.top107671, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-36972954

RESUMO

Mosquitoes are considered the world's deadliest animal because of the pathogens they spread. Additionally, they are an unbearable nuisance in many areas. Visual stimuli play an important role in the mosquito life cycle, helping them find vertebrate hosts, floral nectar, and oviposition sites. Here, we review mosquito vision, including its influences on mosquito behavior, the photoreceptors involved, and mosquito spectral sensitivity, as well as provide an overview of techniques used for the analysis of mosquito vision, including electroretinograms, single-cell recordings, and the use of opsin-deficient mutants. We anticipate that this information will be useful for researchers studying mosquito physiology, evolution, ecology, and management.


Assuntos
Culicidae , Visão Ocular , Animais , Feminino , Culicidae/fisiologia , Eletrofisiologia/métodos
10.
Biosensors (Basel) ; 13(2)2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36832031

RESUMO

Owing to its capacity to eliminate a long-standing methodological limitation, fiber photometry can assist research gaining novel insight into neural systems. Fiber photometry can reveal artifact-free neural activity under deep brain stimulation (DBS). Although evoking neural potential with DBS is an effective method for mediating neural activity and neural function, the relationship between DBS-evoked neural Ca2+ change and DBS-evoked neural electrophysiology remains unknown. Therefore, in this study, a self-assembled optrode was demonstrated as a DBS stimulator and an optical biosensor capable of concurrently recording Ca2+ fluorescence and electrophysiological signals. Before the in vivo experiment, the volume of tissue activated (VTA) was estimated, and the simulated Ca2+ signals were presented using Monte Carlo (MC) simulation to approach the realistic in vivo environment. When VTA and the simulated Ca2+ signals were combined, the distribution of simulated Ca2+ fluorescence signals matched the VTA region. In addition, the in vivo experiment revealed a correlation between the local field potential (LFP) and the Ca2+ fluorescence signal in the evoked region, revealing the relationship between electrophysiology and the performance of neural Ca2+ concentration behavior. Concurrent with the VTA volume, simulated Ca2+ intensity, and the in vivo experiment, these data suggested that the behavior of neural electrophysiology was consistent with the phenomenon of Ca2+ influx to neurons.


Assuntos
Cálcio , Tálamo , Fluorescência , Tálamo/fisiologia , Simulação por Computador , Eletrofisiologia/métodos
11.
Artigo em Inglês | MEDLINE | ID: mdl-35471741

RESUMO

Forty years ago, the introduction of a new electrophysiological technique, the patch clamp, revolutionized the fields of Cellular Physiology and Biophysics, providing for the first time the possibility of describing the behavior of a single protein, an ion-permeable channel of the cell plasma membrane, in its physiological environment. The new approach was actually much more potent and versatile than initially envisaged, and it has evolved into several different modalities that have radically changed our knowledge of how cells (not only the classical "electrically excitable "ones, such as nerves and muscles) use electrical signaling to modulate and organize their activity. This review aims at telling the history of the background from which the new technique evolved and at analyzing some of its more recent developments.


Assuntos
Fenômenos Eletrofisiológicos , Canais Iônicos , Humanos , Canais Iônicos/fisiologia , Membrana Celular/metabolismo , Eletrofisiologia/métodos , Eletrofisiologia Cardíaca
12.
Elife ; 112022 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-36355598

RESUMO

A wide range of techniques in neuroscience involve placing individual probes at precise locations in the brain. However, large-scale measurement and manipulation of the brain using such methods have been severely limited by the inability to miniaturize systems for probe positioning. Here, we present a fundamentally new, remote-controlled micropositioning approach composed of novel phase-change material-filled resistive heater micro-grippers arranged in an inchworm motor configuration. The microscopic dimensions, stability, gentle gripping action, individual electronic control, and high packing density of the grippers allow micrometer-precision independent positioning of many arbitrarily shaped probes using a single piezo actuator. This multi-probe single-actuator design significantly reduces the size and weight and allows for potential automation of microdrives. We demonstrate accurate placement of multiple electrodes into the rat hippocampus in vivo in acute and chronic preparations. Our robotic microdrive technology should therefore enable the scaling up of many types of multi-probe applications in neuroscience and other fields.


Assuntos
Neurônios , Procedimentos Cirúrgicos Robóticos , Animais , Ratos , Eletrofisiologia/métodos , Eletrodos Implantados , Encéfalo
13.
J Neural Eng ; 19(5)2022 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-36214526

RESUMO

Objective.Biomedical instrumentation and clinical systems for electrophysiology rely on electrodes and wires for sensing and transmission of bioelectric signals. However, this electronic approach constrains bandwidth, signal conditioning circuit designs, and the number of channels in invasive or miniature devices. This paper demonstrates an alternative approach using light to sense and transmit the electrophysiological signals.Approach.We develop a sensing, passive, fluorophore-free optrode based on the birefringence property of liquid crystals (LCs) operating at the microscale.Main results.We show that these optrodes can have the appropriate linearity (µ± s.d.: 99.4 ± 0.5%,n = 11 devices), relative responsivity (µ± s.d.: 57 ± 12%V-1,n = 5 devices), and bandwidth (µ± s.d.: 11.1 ± 0.7 kHz,n = 7 devices) for transducing electrophysiology signals into the optical domain. We report capture of rabbit cardiac sinoatrial electrograms and stimulus-evoked compound action potentials from the rabbit sciatic nerve. We also demonstrate miniaturisation potential by fabricating multi-optrode arrays, by developing a process that automatically matches each transducer element area with that of its corresponding biological interface.Significance.Our method of employing LCs to convert bioelectric signals into the optical domain will pave the way for the deployment of high-bandwidth optical telecommunications techniques in ultra-miniature clinical diagnostic and research laboratory neural and cardiac interfaces.


Assuntos
Cristais Líquidos , Potenciais de Ação/fisiologia , Animais , Fenômenos Eletrofisiológicos , Eletrofisiologia/métodos , Cristais Líquidos/química , Coelhos , Transdutores
14.
Int J Mol Sci ; 23(19)2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36232917

RESUMO

Over the last two decades the combination of brain slice patch clamp electrophysiology with optogenetic stimulation has proven to be a powerful approach to analyze the architecture of neural circuits and (experience-dependent) synaptic plasticity in such networks. Using this combination of methods, originally termed channelrhodopsin-assisted circuit mapping (CRACM), a multitude of measures of synaptic functioning can be taken. The current review discusses their rationale, current applications in the field, and their associated caveats. Specifically, the review addresses: (1) How to assess the presence of synaptic connections, both in terms of ionotropic versus metabotropic receptor signaling, and in terms of mono- versus polysynaptic connectivity. (2) How to acquire and interpret measures for synaptic strength and function, like AMPAR/NMDAR, AMPAR rectification, paired-pulse ratio (PPR), coefficient of variance and input-specific quantal sizes. We also address how synaptic modulation by G protein-coupled receptors can be studied with pharmacological approaches and advanced technology. (3) Finally, we elaborate on advances on the use of dual color optogenetics in concurrent investigation of multiple synaptic pathways. Overall, with this review we seek to provide practical insights into the methods used to study neural circuits and synapses, by combining optogenetics and patch-clamp electrophysiology.


Assuntos
Optogenética , Sinapses , Channelrhodopsins , Eletrofisiologia/métodos , Optogenética/métodos , Técnicas de Patch-Clamp , Sinapses/fisiologia , Transmissão Sináptica
15.
Eur Biophys J ; 51(6): 503-514, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35930029

RESUMO

Cultured neuronal networks (CNNs) are powerful tools for studying how neuronal representation and adaptation emerge in networks of controlled populations of neurons. To ensure the interaction of a CNN and an artificial setting, reliable operation in both open and closed loops should be provided. In this study, we integrated optogenetic stimulation with microelectrode array (MEA) recordings using a digital micromirror device and developed an improved research tool with a 64-channel interface for neuronal network control and data acquisition. We determined the ideal stimulation parameters including light intensity, frequency, and duty cycle for our configuration. This resulted in robust and reproducible neuronal responses. We also demonstrated both open and closed loop configurations in the new platform involving multiple bidirectional channels. Unlike previous approaches that combined optogenetic stimulation and MEA recordings, we did not use binary grid patterns, but assigned an adjustable-size, non-binary optical spot to each electrode. This approach allowed simultaneous use of multiple input-output channels and facilitated adaptation of the stimulation parameters. Hence, we advanced a 64-channel interface in that each channel can be controlled individually in both directions simultaneously without any interference or interrupts. The presented setup meets the requirements of research in neuronal plasticity, network encoding and representation, closed-loop control of firing rate and synchronization. Researchers who develop closed-loop control techniques and adaptive stimulation strategies for network activity will benefit much from this novel setup.


Assuntos
Neurônios , Optogenética , Eletrofisiologia/métodos , Microeletrodos , Optogenética/métodos
16.
ACS Nano ; 16(7): 10692-10700, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35786946

RESUMO

Microscale needle-like electrode technologies offer in vivo extracellular recording with a high spatiotemporal resolution. Further miniaturization of needles to nanoscale minimizes tissue injuries; however, a reduced electrode area increases electrical impedance that degrades the quality of neuronal signal recording. We overcome this limitation by fabricating a 300 nm tip diameter and 200 µm long needle electrode where the amplitude gain with a high-impedance electrode (>15 MΩ, 1 kHz) was improved from 0.54 (-5.4 dB) to 0.89 (-1.0 dB) by stacking it on an amplifier module of source follower. The nanoelectrode provided the recording of both local field potential (<300 Hz) and action potential (>500 Hz) in the mouse cortex, in contrast to the electrode without the amplifier. These results suggest that microelectrodes can be further minimized by the proposed amplifier configuration for low-invasive recording and electrophysiological studies in submicron areas in tissues, such as dendrites and axons.


Assuntos
Amplificadores Eletrônicos , Neurônios , Animais , Camundongos , Potenciais de Ação/fisiologia , Eletrofisiologia/métodos , Microeletrodos , Neurônios/fisiologia
17.
J Neural Eng ; 19(3)2022 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-35421850

RESUMO

Objective. Understanding the function of brain cortices requires simultaneous investigation at multiple spatial and temporal scales and to link neural activity to an animal's behavior. A major challenge is to measure within- and across-layer information in actively behaving animals, in particular in mice that have become a major species in neuroscience due to an extensive genetic toolkit. Here we describe the Hybrid Drive, a new chronic implant for mice that combines tetrode arrays to record within-layer information with silicon probes to simultaneously measure across-layer information.Approach. The design of our device combines up to 14 tetrodes and 2 silicon probes, that can be arranged in custom arrays to generate unique areas-specific (and multi-area) layouts.Main results. We show that large numbers of neurons and layer-resolved local field potentials can be recorded from the same brain region across weeks without loss in electrophysiological signal quality. The drive's lightweight structure (≈3.5 g) leaves animal behavior largely unchanged, compared to other tetrode drives, during a variety of experimental paradigms. We demonstrate how the data collected with the Hybrid Drive allow state-of-the-art analysis in a series of experiments linking the spiking activity of CA1 pyramidal layer neurons to the oscillatory activity across hippocampal layers.Significance. Our new device fits a gap in the existing technology and increases the range and precision of questions that can be addressed about neural computations in freely behaving mice.


Assuntos
Fenômenos Eletrofisiológicos , Silício , Animais , Comportamento Animal/fisiologia , Eletrofisiologia/métodos , Camundongos , Neurônios/fisiologia
18.
Elife ; 112022 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-35156923

RESUMO

Optical control of neural ensemble activity is crucial for understanding brain function and disease, yet no technology can achieve optogenetic control of very large numbers of neurons at an extremely fast rate over a large volume. State-of-the-art multiphoton holographic optogenetics requires high-power illumination that only addresses relatively small populations of neurons in parallel. Conversely, one-photon holographic techniques can stimulate more neurons with two to three orders lower power, but with limited resolution or addressable volume. Perhaps most problematically, two-photon holographic optogenetic systems are extremely expensive and sophisticated which has precluded their broader adoption in the neuroscience community. To address this technical gap, we introduce a new one-photon light sculpting technique, three-dimensional multi-site random access photostimulation (3D-MAP), that overcomes these limitations by modulating light dynamically, both in the spatial and in the angular domain at multi-kHz rates. We use 3D-MAP to interrogate neural circuits in 3D and demonstrate simultaneous photostimulation and imaging of dozens of user-selected neurons in the intact mouse brain in vivo with high spatio-temporal resolution. 3D-MAP can be broadly adopted for high-throughput all-optical interrogation of brain circuits owing to its powerful combination of scale, speed, simplicity, and cost.


Assuntos
Holografia/métodos , Neurônios/fisiologia , Estimulação Luminosa/métodos , Fótons , Córtex Visual/fisiologia , Animais , Animais Recém-Nascidos , Encéfalo/fisiologia , Encéfalo/efeitos da radiação , Eletrofisiologia/métodos , Camundongos , Optogenética/métodos , Córtex Visual/citologia
19.
Elife ; 112022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34982027

RESUMO

Behavioral strategies require gating of premature responses to optimize outcomes. Several brain areas control impulsive actions, but the neuronal basis of natural variation in impulsivity between individuals remains largely unknown. Here, by combining a Go/No-Go behavioral assay with resting-state (rs) functional MRI in mice, we identified the subthalamic nucleus (STN), a known gate for motor control in the basal ganglia, as a major hotspot for trait impulsivity. In vivo recorded STN neural activity encoded impulsive action as a separable state from basic motor control, characterized by decoupled STN/substantia nigra pars reticulata (SNr) mesoscale networks. Optogenetic modulation of STN activity bidirectionally controlled impulsive behavior. Pharmacological and genetic manipulations showed that these impulsive actions are modulated by metabotropic glutamate receptor 4 (mGlu4) function in STN and its coupling to SNr in a behavioral trait-dependent manner, and independently of general motor function. In conclusion, STN circuitry multiplexes motor control and trait impulsivity, which are molecularly dissociated by mGlu4. This provides a potential mechanism for the genetic modulation of impulsive behavior, a clinically relevant predictor for developing psychiatric disorders associated with impulsivity.


Assuntos
Comportamento Impulsivo , Receptores de Glutamato Metabotrópico/genética , Receptores de Glutamato Metabotrópico/metabolismo , Núcleo Subtalâmico/fisiologia , Animais , Gânglios da Base/fisiologia , Linhagem Celular , Estimulação Encefálica Profunda , Eletrofisiologia/métodos , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Vias Neurais/fisiologia , Optogenética/métodos
20.
ACS Appl Mater Interfaces ; 14(4): 6120-6130, 2022 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-35073482

RESUMO

In this research, real-time monitoring of lipid membrane disruption is made possible by exploiting the dynamic properties of model lipid bilayers formed at oil-water interfaces. This involves tracking an electrical signal generated through rhythmic membrane perturbation translated into the adsorption and penetration of charged species within the membrane. Importantly, this allows for the detection of membrane surface interactions that occur prior to pore formation that may be otherwise undetected. The requisite dynamic membranes for this approach are made possible through the droplet interface bilayer (DIB) technique. Membranes are formed at the interface of lipid monolayer-coated aqueous droplets submerged in oil. We present how cyclically alternating the membrane area leads to the generation of mechanoelectric current. This current is negligible without a transmembrane voltage until a composition mismatch between the membrane monolayers is produced, such as a one-sided accumulation of disruptive agents. The generated mechanoelectric current is then eliminated when an applied electric field compensates for this asymmetry, enabling measurement of the transmembrane potential offset. Tracking the compensating voltage with respect to time then reveals the gradual accumulation of disruptive agents prior to membrane permeabilization. The innovation of this work is emphasized in its ability to continuously track membrane surface activity, highlighting the initial interaction steps of membrane disruption. In this paper, we begin by validating our proposed approach against measurements taken for fixed composition membranes using standard electrophysiological techniques. Next, we investigate surfactant adsorption, including hexadecyltrimethylammonium bromide (CTAB, cationic) and sodium decyl sulfate (SDS, anionic), demonstrating the ability to track adsorption prior to disruption. Finally, we investigate the penetration of lipid membranes by melittin, confirming that the peptide insertion and disruption mechanics are, in part, modulated by membrane composition.


Assuntos
Bicamadas Lipídicas/metabolismo , Cetrimônio/química , Capacitância Elétrica , Eletrofisiologia/métodos , Bicamadas Lipídicas/química , Meliteno/química , Meliteno/metabolismo , Permeabilidade , Fosfatidilcolinas/química , Fosfatidilcolinas/metabolismo , Dodecilsulfato de Sódio/química , Eletricidade Estática , Tensoativos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...